Advanced Search

XIAO Qifeng1, JIANG Shaobin1, ZHENG Defang1, JIANG Dongdong1, ZHANG Zhuo1, WANG Weibo1, XIAO Chengming1
(Yalong River Hydropower Development Co., Ltd., Chengdu 610051, China)

  • This paper presents a case of inter-turn short circuit in a rotor magnetic pole caused by aging and damage of the inter-turn insulation paper. Through fault analysis and investigation, the root cause and exact fault location were accurately identified. In addition, this paper provides fault analysis and preventive control measures for inter-turn short circuits in rotor magnetic poles of hydro-generators, offering a reference for peers in resolving similar problems.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return