宽负荷运行下300 MW燃煤机组一次风机失速原因分析及防范措施

Cause Analysis of Primary Air Fan Stall and Preventive Measures for 300 MW Coal-Fired Units Under Wide-Load Operation

  • 摘要: 随着燃煤机组频繁参与深度调峰,宽负荷运行已成为常态,导致一次风机在中低负荷工况下面临严峻的失速风险。本研究针对华电淄博热电有限公司#5机组,开展了300 MW、225 MW及150 MW三个典型负荷工况下的现场热态性能试验。试验结果表明:在300 MW满负荷工况下,一次风机运行参数与设计值匹配良好,运行点远离失速线。但在低负荷工况下,风机运行状态严重偏离设计区间,动叶开度偏差高达16%,运行工作点逼近实际失速线。分析认为,为适配低负荷风量需求而被迫增大的动叶开度导致工况点偏离,是引发失速的主要原因。对此,本文提出了在DCS中增设双风机流量与母管压力偏置逻辑、建立运行基准值监测以及加强密封部件维护等防范措施,为同类燃煤机组深度调峰工况下一次风机的安全经济运行提供工程参考。

     

    Abstract: With coal-fired units frequently engaging in deep peak shaving, wide-load operation has become the norm, exposing primary air fans to severe stall risks under medium and low load conditions. Targeting Unit #5 of Huadian Zibo Thermal Power Co., Ltd., this study conducted on-site thermal performance tests under three typical load conditions: 300 MW, 225 MW, and 150 MW. The test results show that under the 300 MW full-load condition, the operating parameters of the primary air fan match well with the design values, and the operating point is far from the stall line. However, under low-load conditions, the fan"s operating state deviates significantly from the design range, with the moving blade opening deviation reaching as high as 16%, and the operating point approaching the actual stall line. Analysis indicates that the main cause of the stall is the deviation of the operating point resulting from the forced increase in moving blade opening to meet the air volume demand under low loads. In response, this paper proposes preventive measures such as adding dual-fan flow and header pressure bias logic in the DCS, establishing operating reference value monitoring, and strengthening the maintenance of sealing components. These measures provide engineering reference for the safe and economic operation of primary air fans in similar coal-fired units under deep peak shaving conditions.

     

/

返回文章
返回