110kv降压变电所设计

Design of 110KV step-down substation

  • 摘要: 在国家工业现代化与经济持续增长的背景下,电能需求不断增加,变电所作为电力系统中关键设备,在电能传输与分配中具有重要作用,电力系统的安全稳定性以及运行的灵活性、经济性很大程度上取决于变电所设计的质量。本文以某工业园区110kV变电站一次侧主接线设计为研究对象,通过查阅资料、调研分析,结合负荷计算确定变压器容量,并设计主接线方案。研究内容包括主接线设计、主变选择、短路电流计算、电气设备选择等。具体工作涵盖:(1)主接线方案选择110kV单母线分段、35kV单母线分段、10kV双母线接线;(2)选用有载调压三绕组变压器,确定绕组接线方式;(2)主接线方案选择35kV单母线分段、10kV双母线接线;(3)根据等值电路、计算短路电流;(4)简要叙述了一次设备选型原则。

     

    Abstract: Against the backdrop of national industrial modernization and sustained economic growth, the demand for electric energy is continuously increasing. As a key device in the power system, substations play a crucial role in the transmission and distribution of electric energy. The safety, stability, flexibility, and economy of the power system largely depend on the quality of substation design. This paper takes the primary side main wiring design of a 110kV substation in an industrial park as the research object. Through consulting relevant materials, conducting research and analysis, and combining load calculations to determine transformer capacity, the main wiring scheme is designed. The research content includes main wiring design, selection of main transformers, short-circuit current calculation, and selection of electrical equipment. The specific work covers: (1) selection of main wiring scheme: 110kV single busbar sectionalization, 35kV single busbar sectionalization, and 10kV double busbar wiring; (2) selection of on-load tap-changer three-winding transformers and determination of winding wiring methods; (3) selection of main wiring scheme: 35kV single busbar sectionalization and 10kV double busbar wiring; (4) calculation of short-circuit current based on equivalent circuits; (5) briefly describing the principles of primary equipment selection.

     

/

返回文章
返回