某550MW水轮发电机转子磁极匝间短路故障情况及处理分析
XIAO Qifeng1, JIANG Shaobin1, ZHENG Defang1, JIANG Dongdong1, ZHANG Zhuo1, WANG Weibo1, XIAO Chengming1
(Yalong River Hydropower Development Co., Ltd., Chengdu 610051, China)
-
摘要: 本文介绍了一起因磁极匝间绝缘纸老化破损导致的磁极匝间短路案例,通过故障分析查找,精准锁定了故障原因与故障部位。并且提供了水轮发电机转子磁极匝间短路故障分析及预控措施,为同行解决类似问题提供参考。Abstract: This paper presents a case of inter-turn short circuit in a rotor magnetic pole caused by aging and damage of the inter-turn insulation paper. Through fault analysis and investigation, the root cause and exact fault location were accurately identified. In addition, this paper provides fault analysis and preventive control measures for inter-turn short circuits in rotor magnetic poles of hydro-generators, offering a reference for peers in resolving similar problems.
下载: