考虑换相次数约束的低压配电网三相不平衡治理方法研究

Research on Three-Phase Unbalance Control Method for Low-Voltage Distribution Network Considering Constraint on Phase-Switching Times

  • 摘要: 针对低压配电网单相用户相别分配不均所引起的三相负荷失衡问题,提出一种计及换相次数约束的负荷重构方法。该方法以降低三相负荷不平衡度为核心目标,在模型中设置换相次数上限,并结合低压径向馈线近似电压降模型,对重构前后的负荷分布、电压水平和线损变化进行对比。算例结果表明,9用户算例不平衡度由61.29%降至4.55%;30用户算例由43.65%降至2.45%,线损由8.36 kW降至8.04 kW。上述结果说明,该方法可通过较少换相操作改善三相负荷分布。

     

    Abstract: To address the three-phase load unbalance caused by uneven phase allocation of single-phase users in low-voltage distribution networks, a load reconfiguration method considering the constraint on phase-switching times is proposed. The method takes the reduction of three-phase load unbalance degree as the main objective, sets an upper limit on phase-switching times in the model, and combines an approximate voltage-drop model of low-voltage radial feeders to compare the load distribution, voltage level and line loss before and after reconfiguration. The case results show that the unbalance degree of the 9-user case decreases from 61.29% to 4.55%; in the 30-user case, the unbalance degree decreases from 43.65% to 2.45%, and the line loss decreases from 8.36 kW to 8.04 kW. The results indicate that the proposed method can improve three-phase load distribution with fewer phase-switching operations.

     

/