变电站主变油色谱异常分析与处理措施

Analysis and Treatment Measures for Abnormal Oil Chromatography of Main Transformer in Substation

  • 摘要: 电网运行过程中,变压器是不可或缺的核心设备,依靠变压实现电能的升压、降压与跨区域输送,设备运行是否平稳,会直接影响片区电网供电稳定。变压器油箱加注的绝缘油,现场实际运行中既要隔绝绕组起到绝缘防护效果,还能带走设备运行产生的热量,内部出现电弧故障时也能起到灭弧作用。设备内部部件故障产生局部高温后,浸泡在构件外侧的绝缘油受热分解,产生各类溶于油液的故障特征气体。日常变电运维工作中,我们 大多通过绝缘油取样做色谱化验,对比气体组分和历次化验数据,提早发现设备潜藏故障。

     

    Abstract: In power grid operation, transformers are essential core equipment. They realize the step-up, step-down and cross-regional transmission of electric energy through voltage transformation, and their stable operation directly affects the power supply reliability of regional power grids. The insulating oil filled in the transformer tank insulates windings to avoid insulation breakdown, takes away heat produced during equipment operation, and extinguishes arcs when internal arc faults happen. When local overheating occurs due to failures of internal components, the surrounding insulating oil decomposes under high temperature and generates various fault characteristic gases soluble in oil. In routine substation operation and maintenance, insulating oil samples are commonly collected for chromatographic analysis. Potential hidden faults can be detected early by comparing gas components with historical test data.

     

/