冉剑华1,谭莉2,张翔宇1,严鸿宇3,成守花3,黄畅4,杨肖5,谭思润6,方杰1,邓宇亮1,林国智1,陈政*
Research on Empirical Formula of Micro-water and Dew Point of SF6 Based on MATLAB
-
摘要: 在常规的SF6微水测试中,往往需要先测出露点温度,再根据露点温度通过查表的方式得到微水值,当需要处理的数据较多时,会明显增加工作量。为降低数据较多的情况下的工作量,本文使用了MATLAB中的cftool曲线拟合工具,对SF6微水露点对应表的数据进行处理,提出了微水和露点在-60℃,0℃区间内的经验公式,并用MATLAB编程计算,证明了该经验公式在-60℃,0℃区间内的准确性。Abstract: In the conventional SF6 micro-water test, it is often necessary to measure the dew point temperature first, and then obtain the micro-water value by looking up the table according to the dew point temperature. When there is a lot of data to be processed, the workload will be significantly increased. In order to reduce the workload when there are a lot of data, this paper uses the cftool curve fitting tool in MATLAB to process the data in the corresponding table of SF6 micro-water dew point, puts forward the empirical formula of micro-water and dew point within the range of -60℃,0℃, and uses MATLAB programming to calculate. It is proved that the empirical formula is accurate in the interval of -60℃,0℃.
下载: