高级检索

基于结构力学仿真的220kV变压器套管接线柱变形缺陷分析*

Analysis of the Deformation Defect of a 220kV Transformer Bushing Terminal Based on Mechanical Simulation

  • 摘要: 对一起220kV变压器套管接线柱变形缺陷,开展了接线柱成分、硬度、弯曲、拉伸等力学性能检测,并对套管头部结构建模开展静力学仿真分析;阐述了接线柱区域为应力集中区域,而套管接线柱机械性能不足,导致在引下线重力与风荷载作用下,接线柱应力超过材料的屈服强度而发生弯曲变形;提出了改进建议,为套管运行维护提供参考。

     

    Abstract: This paper introduces a deformation defect of a 220kV transformer bushing terminal. The mechanical properties of the terminal, such as composition, hardness, bending and tensile, were tested, and static simulation analysis was carried out on the model of the bushing head structure. It is expounded that the bushing terminal is a stress concentrated area, and its mechanical properties are insufficient, which leads to the bending deformation of the terminal due to the stress exceeding the yield strength of the material under the action of gravity and wind load. Suggestions for improvement were put forward to provide reference for bushing operation and maintenance.

     

/

返回文章