某循环流化床锅炉水冷壁管泄漏原因分析与处理措施
Analysis of Leakage Causes and Treatment Measures for Water-Cooled Wall Tubes in a Circulating Fluidized Bed Boiler
-
摘要: 探究循环流化床锅炉水冷壁管泄漏原因,通过对爆口处进行宏观检查、金相组织、硬度值及力学性能等进行分析。结果表明此次爆管原因为水冷壁管壁被吹损减薄至材料强度不够而导致爆口。同时就该水冷壁管的监督检测及处理措施进行讨论。Abstract: This paper mainly to study the leakage of Water-Cooled Wall Tubes of Circulating Fluidized Bed Boilers. Through the macro inspection, metallographic analysis, hardness testing and mechanical property evaluation. The results showed that the tube rupture was caused by wall erosion thinning the material beyond its strength capacity. Additionally, the inspection and treatment measures for the water-cooled wall tubes were discussed.