  • 摘要: 为解决配电变压器不停电更换装置长期作业时连接结构因应力集中和循环载荷易造成疲劳断裂的问题,基于ANSYS Workbench软件对该装置中连接结构开展静力学仿真与疲劳寿命分析,并通过侧板加厚、圆弧过渡和底部加装底板3种不同方案进行探讨。仿真结果表明:该装置连接结构应力集中部位位于顶板与侧板连接处,底板加厚对结构性能改善最为显著,优化后方案能对后续实际工程应用提供参考依据。

     

    Abstract: In order to solve the problem of fatigue fracture of the connection structure caused by stress concentration and cyclic load during the long-term operation of the non-stop replacement device of the distribution transformer, this study utilizes ANSYS Workbench software to conduct static simulation and fatigue life analysis of the connection structure. Three different improvement schemes are investigated: side plate thickening, arc transition, and bottom plate installation. Simulation results indicate that the stress concentration area of the connection structure is located at the junction of the top plate and side plate. Among the schemes, bottom plate thickening demonstrates the most significant improvement in structural performance. The optimized solution can provide a reference for subsequent practical engineering applications.

     

/