高级检索

基于倍频谐波信息的有源配电网电流差动保护研究

Research on Active Distribution Network Current Differential Protection Based on Frequency Doubling Harmonic Information

  • 摘要: 针对有源配电网中分布式电源接入导致故障电流复杂化、传统保护易误动或拒动的问题,提出一种基于倍频谐波信息的电流差动保护方法。通过Prony算法提取故障电流中的倍频谐波分量,构建差动保护判据,实现故障区域的快速、准确识别与隔离。仿真结果表明,该方法在多种故障场景下均能有效区分区内、区外故障,提升保护动作的可靠性与速动性,适用于高比例分布式电源接入的配电网保护。

     

    Abstract: This paper proposes a current differential protection method based on harmonic information to address the problems of complex fault currents caused by the integration of distributed power sources in active distribution networks and the susceptibility of traditional protections to misoperation or refusal. By using the Prony algorithm to extract the harmonic components of the fault current, a differential protection criterion is constructed to achieve rapid and accurate identification and isolation of the fault area. The simulation results show that this method can effectively distinguish faults within and outside the zone in various fault scenarios, improve the reliability and speed of protection actions, and is suitable for distribution network protection with high proportion of distributed power access.

     

/

返回文章
返回