基于传感器扰动补偿的变流器开路故障检测方法

Sensor Disturbance Compensation-based Power Converter Fault Detect Method

  • 摘要: 针对基于状态观测器模型的变流器开路故障诊断方法检测过程中,由于传感器故障或噪声的扰动造成测量数据失准,带来的检测正确率下降的问题,提出了一种基于传感器扰动补偿的变流器开路故障检测方法。该方法通过建立混合逻辑动态直流电压观测器模型和构建故障特征函数,实现开路故障初步检测;基于H∞理论设计传感器检测量观测器,构造扰动特征函数,用于扰动检测与定位;在原本的故障特征函数中,引入扰动补偿环节,以实现传感器扰动影响下变流器开路故障的精准鲁棒检测。通过MATLAB/Simulink仿真平台进行了方法验证和对比分析。

     

    Abstract: Aiming at the problem that the detection accuracy decreases due to inaccurate measured data caused by sensor disturbances in the detection process of the open-circuit fault diagnosis method, this paper proposes an open-circuit fault detection method for converters based on sensor disturbance compensation. This method realizes the preliminary detection of open-circuit faults by establishing a DC voltage observer model and fault characteristic function. Based on the H∞ theory, a sensor measurement observer is designed, a disturbance characteristic function is constructed for disturbance detection and location. A disturbance compensation link is introduced into the original fault characteristic function to achieve accurate and robust detection. The method verification and comparative analysis are carried out on the MATLAB/Simulink simulation platform.

     

/