  • 摘要: 针对工业企业电力负荷波动对干式电除尘器运行效率和经济性的影响,建立了基于电力负荷波动的运行优化策略。通过分析负荷波动特征及其对除尘器电压稳定性和运行成本的影响机制,构建了负荷预测模型、电气参数动态调节和机械运行参数优化的综合优化方案。以某钢铁企业180 m2烧结机配套除尘器为例进行验证,结果表明除尘效率从98.5%提升至99.2%,年节电率达19.4%,项目投资回收期为2.6年。

     

    Abstract: In response to the impact of power load fluctuations in industrial enterprises on the operational efficiency and economy of dry electrostatic precipitators, this paper establishes an operational optimization strategy based on power load fluctuations. By analyzing the characteristics of load fluctuations and their influence mechanisms on the voltage stability and operating costs of dust collectors, a comprehensive optimization scheme was constructed, including a load forecasting model, dynamic adjustment of electrical parameters, and optimization of mechanical operating parameters. Taking the dust collector of a 180 m2 sintering machine in a certain steel enterprise as an example for verification, the results show that the dust removal efficiency has increased from 98.5% to 99.2%, the annual electricity-saving rate has reached 19.4%, and the payback period of the project investment is 2.6 years.

     

/