某火力发电厂4号发电机端部结构松动故障分析与处理
Analysis and Treatment of End Structure Loosening Fault in No.4 Generator at a Thermal Power Plant
-
摘要: 介绍了一起汽轮发电机连续两次发生的定子铁芯松动故障。该故障主要表现为汽端铁芯局部松动、励端气隙隔板把合螺杆断裂脱落及汽端定位筋螺母松动等,给出日常工作中的措施建议,防范此类事件再次发生。Abstract: This article introduces the problem of stator core looseness in a steam turbine generator that was discovered twice, mainly manifested as local looseness of the steam end core, fracture and detachment of the coupling screw of the excitation end air gap baffle, and loosening of the steam end positioning rib nut. Based on this incident, measures and suggestions for daily work are given to prevent such incidents from happening again.
下载: