高级检索

电力系统暂态功角稳定裕度计算方法综述

Summary of Calculation Methods for Transient Power Angle Stability Margin of Power System

  • 摘要: 随着新能源渗透率增加,电力系统惯量、阻尼逐渐降低,暂态功角稳定性问题日渐凸显。为更加精细评估电力系统暂态功角稳定性,需要对暂态功角稳定裕度进行定量描述。综述了最大功角差裕度计算法、故障临界切除时间裕度计算法、轨迹分析裕度计算法和发电机功角轨迹簇积分裕度计算法这4种主流暂态功角稳定裕度的计算方法。对比4种计算方法的适应性和准确性,为相关问题研究的进一步开展提供有益借鉴。

     

    Abstract: With the increase of new energy penetration, the inertia and damping of the power system gradually decrease, and the transient power angle stability problem becomes increasingly prominent. In order to further evaluate the transient power angle stability of power system, it is necessary to quantitatively describe the transient power angle stability margin. In this paper, four main transient power angle stability margin calculation methods are summarized, including the maximum power angle difference margin calculation method, the fault critical removal time margin calculation method, the trajectory analysis margin calculation method and the generator power angle trajectory cluster integration margin calculation method. The adaptability and accuracy of four calculation methods were compared, providing useful references for further research on related issues.

     

/