高级检索

基于FCEEMD和Prony算法的变频系统漏电检测研究

Research on Leakage Detection of Frequency Conversion System Based on FCEEMD and Prony Algorithm

  • 摘要: 变频系统中由于变频器的存在会产生大量的高次谐波与高频脉冲,使得在电力系统输电线路的对地电容上产生零序电流,严重时将影响漏电检测过程中的精确度并漏电保护系统误动作。为此,在分析已有方法的劣势后提出了一种基于快速完全集合经验模态分解法(Fast Complete Ensemble Empirical Mode Decomposition, FCEEMD),并将其与Prony算法相结合应用于漏电检测中。此方法不仅能够有效弥补传统傅里叶分析法的缺陷,而且能够较好地满足漏电保护系统所要求的实时性和精确性要求,并且利用仿真试验验证了其可靠性与实用性。

     

    Abstract: In the frequency conversion system, due to the existence of the frequency converter, a large number of high-order harmonics and high-frequency pulses will be generated, which will create a zero-sequence current on the ground capacitance of the power system transmission line. In severe cases, it will affect the accuracy of the leakage detection process and the misoperation of the leakage protection system. Therefore, after analyzing the disadvantages of the existing methods, this paper proposes a fast complete ensemble empirical mode decomposition(FCEEMD) method, and applies it to the leakage detection by combining it with the Prony algorithm. This method can not only effectively make up for the shortcomings of the traditional Fourier analysis method, but also can better meet the real-time and accuracy requirements of the leakage protection system, and its reliability and practicability are verified by simulation experiments.

     

/